Fluoresbrite BB Carboxylate Micros
Eduardo- 0
INTRODUCTION
Aqua-Poly / Mount is a non-permanent aqueous mounting medium formulated to cover coverslips directly from aqueous solutions. That It is non-fluorescent and has an anti-discoloration component to increase the display time of the sample. Use Aqua-Poly / Mount with most Fluorescent dyes and dyes including DAB, Alkaline Phosphatase Fast Red, AEC (aminoethyl carbazole), and a variety of other chromogens to enhance and retain fluorescent intensity.
Aqua-Poly / Mount can be used for frozen sections, fat stains, chromogens for immunohistochemistry and in situ hybridization as well as other applications that require a water-soluble mounting medium.
Using Aqua-Poly / Mount, the coverslip will dry in 24 to 48 hours depending on the amount of medium used Aqua-Poly / Mount solidifies under a coverslip on the microscope slide after 24 hours under the following laboratory conditions and room temperature; relative humidity in winter above 20% and relative humidity in the summertime up to 50%. It is not necessary to paint the edges of the coverslip. When the medium dries it will form a seal.
PROCESS
Prepare slides as necessary. Before placing the coverslip, rinse the slides in distilled or deionized water. Excess fluid can be drained, but drying is not recommended. Aqua-Poly / Mount is supplied in practical 20 ml dropper bottles for manual use staining and in larger volumes for automatic coverslips.

Apply two drops of Aqua-Poly / Mount to the slide at the end or on the tissue. Gently lower the coverslip at an angle while gently applying pressure to expel excess media and air bubbles from the tissue and underneath the coverslip. It is helpful to bring the coverslip to the edge of the coverslip half and then slowly lower it while applying pressure. Gently tilt the slide to remove any media on the edges of the slide and coverslip. The slide can be seen immediately or after drying. Slides can be dried at room temperature or 4 ° C. Drying at 4 ° C will increase drying times.
Do not heat the slides as this may damage or fade some stains or reactions. Slides containing fluorescent chromogens should be stored in the dark. Aqua-Poly / Mount can be used on automatic coverslips in place of a traditional solvent-based coverslipping medium. The viscosity of the medium may need to be adjusted to obtain proper flow rates. Let the liquid reach room temperature before making any adjustments for flow rate as viscosity will change. The amount of media dispensed will affect the drying time. Thicker sections will require more coverage with medium to ensure that the coverslip remains in place against the surface of the slide.